O-ring 7x2 made of FKM for reliable sealing Scope of delivery 1 Pcs. O-Ring 7x2 FKM Technical specifications - Material: FKM 80 / Vi 840 - Temperature: -46 °C to 200 °C - Color: black - Approvals/Certifications: DIN EN 14141 + API 6A&6D, DVGW DIN EN 682 (Typ GBL), DIN EN 13787
OXY 4100 / 5100 SENSOR CAP TR PTFE 0 TO 2000 ppb (DO)
RMB 12,102.30
Sensor cap for dissolved oxygen measurements with improved chemical resistance and highest measurement stability. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap trace range PTFE Technical specifications - Accuracy at 20 °C : max. ± 1 ppb or ± 3 % - Measuring range: 0 ppb to 2000 ppb - Sample temperature Oxy 4100: -5 °C to + 40 °C, non-freezing - Sample temperature Oxy 5100: -5 °C to + 65 °C, non-freezing - Wetted materials: Stainless steel 1.4404 (AISI 316L), PTFE (FDA-approved) and FKM 75.16-04 (FDA-approved) - Response time: t90 < 100 s
OXY 5100 SENSOR CAP ULTRA-WIDE RANGE 0 TO 45 ppm / 0 TO 100 % O2 (DO / GAS)
RMB 9,028.70
Sensor cap for oxygen measurements in liquids and gases. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap ultra-wide range Technical specifications - Accuracy at 20°C (liquid phase) : max. ± 0.1 ppm or ± 5 % - Accuracy at 20°C (gas phase) : max. ± 0.2 % O2 or ± 5 % - Measuring range (liquid phase) : 0 ppm to 45 ppm - Measuring range (gas phase) : 0 % O2 to 21 % O2 (0 hPa to 1000 hPa) - Sample temperature: -5 °C to +40 °C, non-freezing - Wetted materials: Stainless steel 1.4404 (AISI 316L), Silicone (FDA-approved) and FKM 75.16-04 (FDA-approved) - Certifications: EHEDG (Type EL Class I)
OXY 5100 SENSOR CAP ULTRA-TRACE RANGE 0 TO 200 ppmv (GAS)
RMB 9,028.70
Sensor cap for oxygen measurement in ultra-pure gases such as highly purified CO2 and N2. All required calibration parameters are stored in the sensor cap. The Toolmaster technology detects the sensor cap and transfers all setup parameters to the sensor automatically for quick and easy cap exchange. Scope of delivery 1 Pcs. Sensor cap ultra-trace range Technical specifications - Accuracy at 20°C : max. 2 ppmv or ± 5 % - Measuring range: 0 ppmv to 200 ppmv (0 hPa to 0.2 hPa) - Sample temperature: 0 °C to +40 °C, non-freezing - Wetted materials: Stainless steel 1.4404 (AISI 316L), Silicone and FKM 75.16-04 (FDA-approved) - Unsuitable for CIP/SIP